## What it does

A monitor's maintenance window silences alerts for incidents that open while it's active. Checks keep running on the normal interval, and incidents are still recorded — each one flagged `maintenance: true` on `GET /incidents` (see [Incidents](/docs/incidents/)) if it opened during the window.

What's silenced is the alert, not the incident: no webhook, email, push, or SSE alert goes out for a down or flapping incident that opens inside the window, and its recovery alert is skipped too, but only if every incident that recovery resolves was itself opened during a window. The decision is made once, at the moment an incident opens, with exclusive boundaries at both ends — an incident that opened just before the window started keeps alerting normally. Uptime percentages aren't adjusted for maintenance time either; a down incident during a window still counts against uptime.

## Set it up in the app

1. Open a monitor and click **Edit**, then expand **Advanced**.
2. Set **Maintenance window** to **Every day** or **Once**.
   - **Every day** asks for **Start**, **End**, and **Time zone**. It repeats daily in that zone and can span midnight — for example `23:00`–`03:00`.
   - **Once** asks for **Starts** and **Ends**, a single absolute span.
3. Click **Save**.

![The monitor edit form's Advanced section with Maintenance window set to Every day, showing Start, End, and Time zone fields](/_astro/maintenance-windows-1-form.o5eaC8Op.png)

The monitor's detail page shows a **Maintenance** row summarizing the window, for example `Every day 23:00–03:00 (Europe/Lisbon)`, with a second line reading `Active now · ends in 2h 15m`, `Starts in 40m`, or an ended timestamp, depending on where the window currently sits. Any incident that opened during a window carries a muted **Maintenance** badge in the incidents list, with a tooltip reading "Alerts silenced: opened during a maintenance window."

![The monitor detail page's Overview section showing a Maintenance row with the value Once and the detail line Active now, ends in](/_astro/maintenance-windows-2-detail.1WK8K6EO.png)

## Do the same through the API or MCP

Set a daily window:

```bash
curl -X PUT https://api.monitive.com/api/v1/monitors/1287 \
  -H "Authorization: Bearer $MONITIVE_API_KEY" \
  -H "Content-Type: application/json" \
  -d '{
    "maintenance": {
      "type": "daily",
      "start_time": "23:00",
      "end_time": "03:00",
      "timezone": "Europe/Lisbon"
    }
  }'
```

Or a one-time window, using any RFC3339 offset:

```bash
curl -X PUT https://api.monitive.com/api/v1/monitors/1287 \
  -H "Authorization: Bearer $MONITIVE_API_KEY" \
  -H "Content-Type: application/json" \
  -d '{
    "maintenance": {
      "type": "once",
      "starts_at": "2026-11-01T09:00:00+01:00",
      "ends_at": "2026-11-01T11:00:00+01:00"
    }
  }'
```

The response echoes both timestamps normalized to UTC, regardless of the offset you sent:

```json
{
  "monitor": {
    "maintenance": {
      "type": "once",
      "starts_at": "2026-11-01T08:00:00Z",
      "ends_at": "2026-11-01T10:00:00Z"
    }
  }
}
```

The dashboard (see the screenshot above) displays `once` times in your browser's local time zone, while the API always stores and returns UTC regardless of the offset you sent — don't expect the clock times shown in the app to match a `once` window's UTC values byte-for-byte.

Clear a window back to none:

```bash
curl -X PUT https://api.monitive.com/api/v1/monitors/1287 \
  -H "Authorization: Bearer $MONITIVE_API_KEY" \
  -H "Content-Type: application/json" \
  -d '{"maintenance": {"type": "none"}}'
```

Omitting `maintenance` entirely from a `PUT` leaves the stored window unchanged — it isn't the same as clearing it. `POST /api/v1/monitors` without a `maintenance` field creates the monitor with `{"type":"none"}`. See [Monitors](/docs/monitors/) for the full create/update reference.

Through MCP, both `create_monitor` and `update_monitor` take the same `maintenance` object — ask your agent to put a monitor into maintenance and give it the type and times, and it maps directly to this shape. See [Use Monitive through MCP](/docs/mcp/).

## Plan limits

A monitor has exactly one maintenance window — there's no way to stack several windows on the same monitor (`Maintenance` is a single field on `models.Monitor`, not a list). For a daily window, the time zone must be a real IANA name: an empty string, `Local`, or anything `time.LoadLocation` can't resolve is rejected (`validateMaintenanceTimezone` in um-api's `internal/api/maintenance.go`).

See [Monitors](/docs/monitors/) for the monitor limits a maintenance window shares with every other monitor setting, such as monitor count caps and the 60-second minimum check interval.

## Troubleshooting

**"not allowed for type ..."** You sent a field that doesn't belong to the window's `type` — for example `timezone` on a `once` window, or `starts_at` on a `daily` one. Each type accepts only its own fields.

**"unknown time zone ..."** The `timezone` value isn't a real IANA zone name. `Local` and an empty string are both rejected outright, along with anything `time.LoadLocation` can't resolve.

**"end_time: must differ from start_time"** A daily window's `start_time` and `end_time` must differ. Use the midnight-spanning form (for example `23:00`–`03:00`) instead of setting them equal.

**"ends_at: must be after starts_at"** A `once` window's `ends_at` must come strictly after `starts_at`. Two timestamps that differ by less than a microsecond are treated as equal and rejected the same way, since that's PostgreSQL's `timestamptz` precision.

**"maintenance must not be null"** You sent `"maintenance": null` for the whole field. Omit the field entirely instead — on `PUT` that leaves the stored window unchanged, and on `POST` it defaults to `{"type":"none"}`.

**"maintenance.`<field>`: must not be null"** You sent `null` for a field inside the `maintenance` object, for example `"start_time": null`. Every field a given type requires must be a real value.

**I still got an alert during the window.** The silencing decision is made once, when the incident opens. If the incident opened just before the window started, it alerts normally even though the window became active moments later — the window's boundary is exclusive, so the start instant itself doesn't count as inside it.

**An old incident is still silent after the window ended.** Expected. Once an incident is flagged as having opened during maintenance, it stays silent through to its recovery alert even after the window ends, including across a down-to-flapping handoff.

**Uptime still dropped during the window.** Expected. A maintenance window only silences alerts — it doesn't adjust uptime. A down incident during a window counts against uptime the same as any other.